XAC-A271 Control Handle Switch (2-Button)

The XAC-A271 is a two-button pendant control handle switch with a double-insulated polypropylene enclosure rated IP65, 600 V insulation voltage and one million operating cycles. Supplied on a moulded cable boot for crane and hoist service.
  • Model: XAC-A271
  • Push buttons: 2
  • Degree of protection: IP65
  • Rated insulation voltage (Ui): 600 V, pollution degree 3
  • Mechanical durability: 1,000,000 operating cycles
Share to:

Description

XAC-A271 is a two-button pendant control handle for cranes, hoists and travelling machinery. It puts the two functions of a single motion — or one function in each direction — at the operator’s thumb in a sealed, double-insulated enclosure rated IP65.

Where the XAC-A271 fits

The two-button layout suits machines with a single powered movement, or a station used as a local jog point on larger equipment. Typical duty is hoist lifting and lowering, hatch and door drives, and travel motions on light cranes where the operator walks with the load.

The handle is supplied with a moulded cable boot at the head of the enclosure, which relieves strain on the terminations and shields the cable entry from running water and dust.

Enclosure and ingress protection

The enclosure is moulded in double-insulated polypropylene and coloured yellow throughout, so the station stays visible against machinery and the plastic is the same colour inside and out — a scuff cannot expose a different coloured substrate.

The assembled station is rated IP65: dust-tight, and protected against water projected from a nozzle in any direction. That covers outdoor and dusty indoor service positions; it does not cover immersion.

Electrical shock protection is Class II to IEC 536 and NFC 20-030, so the station relies on double insulation rather than on a protective earth connection.

Contacts and durability

The station uses N/C or N/O slow-break contacts and is rated for a thermal current (Ith) of 10 A, with a rated insulation voltage (Ui) of 600 V at pollution degree 3 and a rated impulse withstand voltage (Uimp) of 6 kV to IEC 947-1.

Mechanical durability is rated at 1,000,000 operating cycles, and the station withstands 100 g shock conforming to IEC 68-2-27 — relevant on crane and hoist duty where the pendant swings and can strike the structure.

Short-circuit protection is by 10 A cartridge fuse, type gG (gL). Provide that protection in the supply to the control circuit.

Wiring and termination

Terminations are screw and captive cable clamp terminals. Acceptable conductor sizes run from a minimum of 1 x 0.5 mm² up to a maximum, with or without a cable end, of 2 x 1.5 mm² or 1 x 2.5 mm².

Terminal referencing follows CENELEC EN 50013, and the station is built to IEC 947-5-1, EN 60947-5-1, IEC 337-1, NFC 63-146 and VDE 0660-200. NEMKO approval applies to the standard station; a special version is available with UL Listed A600-Q600 and CSA A600-Q600 ratings for North American projects.

Specifications

Model XAC-A271
Station type Pendant control handle switch
Push buttons 2 push buttons
Emergency stop Not fitted
Enclosure Double-insulated polypropylene, coloured yellow throughout
Degree of protection IP65
Rated insulation voltage (Ui) 600 V, pollution degree 3
Thermal current (Ith) 10 A
Rated impulse withstand voltage (Uimp) 6 kV conforming to IEC 947-1
Short-circuit protection 10 A cartridge fuse, type gG (gL)
Mechanical durability 1,000,000 operating cycles
Shock resistance 100 g conforming to IEC 68-2-27
Electric shock protection Class II conforming to IEC 536 and NFC 20-030
Contact operation N/C or N/O slow break
Terminal referencing Conforming to CENELEC EN 50013
Cable capacity Screw and captive cable clamp terminals; min. 1 x 0.5 mm², max. with or without cable end 2 x 1.5 mm² or 1 x 2.5 mm²
Standards IEC 947-5-1, EN 60947-5-1, IEC 337-1, NFC 63-146, VDE 0660-200
Approvals NEMKO; special version UL Listed A600-Q600 and CSA A600-Q600
Nameplate rating AC 380 V, 10 A

The example shown carries a nameplate rated AC 380 V, 10 A and a CE mark.

Ordering the XAC-A271 from IEHC

State the supply and control-circuit voltage, the number of functions and their legends, the cable length and diameter, and whether the UL / CSA special version is required.

If the machine also needs an emergency stop at the pendant, compare the XAC-A2713, which adds a mushroom-head emergency stop to the same two-button layout, or the XAC-A6713 for six-button duty. Send your specification to IEHC for a configuration check, or review the wider control handles and pendant switches range.

FAQ

How many buttons does the XAC-A271 have?

Two push buttons. The station does not include an emergency stop.

What protection rating does the XAC-A271 offer?

The assembled station is rated IP65 — dust-tight and protected against water projected from a nozzle in any direction. It is not intended for immersion.

How long does the switch mechanism last?

Mechanical durability is rated at 1,000,000 operating cycles.

Is a UL or CSA rated version available?

Yes. The standard station carries NEMKO approval, and a special version is available with UL Listed A600-Q600 and CSA A600-Q600 ratings. Request it explicitly when ordering.

What cable sizes can be terminated?

Screw and captive cable clamp terminals accept from 1 x 0.5 mm² up to 2 x 1.5 mm² or 1 x 2.5 mm², with or without a cable end.

Request Quote

Interested in this product? Share your requirements or questions using the form.

  • Your requirements

    Include the specifications, options, or quantity you need, if known.

  • Your questions

    Ask about product details, availability, or order information.

  • Your contact details

    Leave an email address where you can receive a reply.

+86-18989776059 Phone iehc1@iehcele.com E-mail Chat on WhatsApp WhatsApp